Description
HAGER TYB602F switching / blind actuator 2/1-fold KNX 6A UP
Flush-mounted switching actuator with integrated bus coupler for switching 2 socket or lighting outputs or 1 roller shutter/blind.
To control lighting outputs, you can choose between ON/OFF, Timer, Safety Off, Forced Control, Lock, Logic, Preset, Delay or 64 Scenes.
With switching function for time or continuous function.
The blind function can be used to adjust the drive command UP/DOWN/STOP and the slat angle.
Percentage control of the blind to move to a predefined position.
With the sun protection function, in conjunction with an outdoor sensor, the brightness per room can be controlled.
With alarm function to control the blind in a defined position.
Safety descent as long as the button remains pressed.
64 scene function per channel.
Logic block to control the output depending on the result of a logical link.
Preset, lock function, forced control.
The device converts the bus information into corresponding commands.
The outputs are switched via the system line from the inputs assigned to them.
Manual control, as well as a switching status indicator by means of LED and operating hours counter per output.
The device can be read with a diagnostic tool.
With programming button and red programming LED, bus connection pre-assembled with cable and bus terminal.
Technical features:
Operating voltage via bus: 21 32 V DC
max. switching capacity at: 230 V AC
Frequency: 50/60 Hz
Switching current at cos = 0.8: max. 6 A
Current consumption bus (data transfer): 7 mA
230 V LED lamps: 5 x 13 W
power Energy-saving lamps: 5 x 13W
230 V Incandescent and halogen lamps: 500 W
Conventional transformers: 500 VA
electronic transformers: 500 W
Fluorescent lamps uncompensated: 500 VA
Fluorescent lamps with electronic ballast: 6 x 48 W
Operating temperature: -5 to 45 degrees Celsius
Conductor cross-section (rigid): 0.75 2.5 mm‚²
Conductor cross-section (flexible): 0.75 2.5 mm‚²
Dimensions (W x H x D): 4.45 x 2.18 x 4.3 cm
– Manual operation in test mode via programming button (single-surface operation), test operation/construction site operation can be activated via programming button
– with illuminated programming button
– with positioning function for blind and slat position, with safety functions e.g. for wind, rain, alarm, with sun protection function
– for controlling a drive for alternating voltage
– Changeover time can be set
when changing direction – for 1 phase operation
– with integrated bus coupler
– bus connection via pre-assembled cable with bus connection terminal
– with screw terminals
– for switching independent loads or for controlling drives.
– Follow the instructions of the engine manufacturer!