Description
Communication via KNX EIB with electronic ballasts (ECG) with a DALI interface
Two DALI outputs with DALI-2 certification acc. to IEC 62386-101 and 103, each for communication with up to 64 DALI ballasts
Integrated power supply with input voltage AC 110…240 V, 50…60 Hz or DC 120…240 V for powering the gateway electronics and DALI output
Support of ECGs Type 0, 1, 2, 3, 4, 5, 6, 7 and 8 according to EN 62386 edition 1 as well as edition 2 (DALI-2)
Maximum DALI output voltage of 19 V, short circuit resistant
Incorrect voltage detection during commissioning, whether incorrect power line is connected to a DALI output
LED display for displaying operation mode and error messages
Pushbutton for switching between bus and direct operating mode
One pair of pushbuttons for switching On/Off of all connected DALI ballasts
One LED per DALI output for status signal of all connected luminaries in direct mode
Configurable behaviour for bus failure (stand-alone mode)
Control (switching, dimming, set dimming value) of all connected luminaries together in broad-cast mode
Status signal and display of lamp and ECG failure per group and per DALI device
One or two level timer
Integrated scene control for up to 32 scenes
Assignment of DALI ECG to groups and test option for ECG, groups and scenes via ETS during commissioning
Possibility to reintegrate defective DALI ECG without software
Integrated bus coupling unit with only half a standard bus load
Bus connection via bus terminal
Mounting on DIN rail EN 60715-TH35-7.5
Additional functionalities GAMMA
The following options are selectable, depending on the application program:
Configurable assignment of max. 128 DALI ECG to max. 32 DALI groups, exclusive controlled in groups or single (switching, dimming, set dimming value and color temperature) and feedback for group status and lamp failure
Support of DALI DT8 ECGs for colour temperature control Tc, Tunable White according to EN 62386 part 209. individual, group, scene, effect and schedule control for Human Centric Lighting (HCL)
Configurable function burn-in for all ECG via pushbutton or single via object
Up to twelve stand-by-area analysis for activation of switch actuators
Distinction between self-contained emergency luminaries with one or two DALI devices
Optional configuration of any DALI ECG to dim to a preset dimming value in case of emergency mode
Locking of switching and dimming commands as well as configuration while emergency mode is activated
Activation of emergency mode based on a configurable number of failed DALI ECG
Lock object to elimination of failure messages interruption of ECG during emergency lighting testing
Inhibit mode for disabling battery mode of self-contained emergency luminaries over pushbutton